At 12:35 PM 6/18/2021, Carl Peterson wrote:
We've gone full circle - Flat to fully routed to
MPLS/VPLS over a routed network back to
flat. You hit a scaling issue with routed
networks as you hit 10G and above, especially if
you aren't using Mikrotik or other low cost
routing. Real carrier grade switching is a lot
lower cost, lower power, and much easier to manage. Â
Every customer has their own dedicated circuit
(SVLAN.CVLAN). The corresponding interface on
the BNG is dynamically created for the
subscriber with attributes out of radius. Â
Something like this isn't the right answer at
100 customers but you should consider it or
something like it once you go north of a few k subs. Â
What are you using for the BNG and does it
require an additional license for dynamic interface creation?
--
AF mailing list
[email protected]
http://af.afmug.com/mailman/listinfo/af_af.afmug.com