What beta version will put all the frequencies back in a 365 so we can do an AP 
EVal easily?—
Sent from Mailbox

On Mon, Sep 22, 2014 at 12:38 PM, canopy01 via Af <[email protected]> wrote:

> Folks,
> PMP Beta load 13.2 Build 30 is now available for download and you can find it 
> here:
> https://support.cambiumnetworks.com/files/pmp450
>   *   Improvements for MIMO-A
>      *   PMP450 APs & SMs will now default to MIMO-A control message mode
>      *   If you have an interop sector (containing 430 SMs), you may need to 
> set this back to legacy SISO mode
>         *   Configuration -> Radio -> PMP 430 Interop Mode, set to SISO
>         *   This is only necessary if you have issues with existing PMP430's 
> reconnecting and should not be necessary in a majority of the cases.
>   *   Fix for missing "None" frequency option
>   *   Control Slots is now called Contention Slots
>   *   Addition of "Color Code Priority" column to the Session Status -> 
> Session tab
>      *   If Color Code Rescan option is enabled on the AP, and an SM is 
> registered via a non-primary color code, there will be a countdown for each 
> SM that will be rescanning due to this configuration.
>      *   If an SM is registered via Installation Color Code (ICC), this will 
> also be noted on the Session Status -> Device tab, Session column, next to 
> "In Session"
>   *   Added number of VCs in use next to Subscriber Count on the AP's main 
> page.  This number includes Broadcast and Multicast (if enabled) VCs.
>   *   Added support to NAT to handle fragments (to fix the FemtoCell issue)
>   *   Alignment tone fix
>   *   Various bug fixes
> Corey