My main site is 8x ePMP 24v with SynInjectors. I'm doing 24v but the distance from the SyncInjector to radio is tops 60 feet of cat5.
20v is when they won't boot. If your runs are 100-200 feet I doubt you'll lose 3.5 volts. I'm not sure what kind of amperage capacity the 750p has, though. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Tue, Dec 15, 2015 at 2:28 PM, Christopher Gray < [email protected]> wrote: > The spec sheet shows ePMP sync radios accept supplies as low as 23V. > > I am currently running 24V systems with ePMP non-sync radios. Does anyone > run 24V systems with ePMP sync radios? My Mikrotik 750UP and 750P outputs > measure only 23.5V, so I'd expect very little room for losses. > > I want to try some, but I don't want to change my power configuration just > yet if I don't have to. > > Thanks - Chris >