Never had any issues with it, roughly 13 months now. Using GIGE-APC-HV surge.
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Tue, Dec 15, 2015 at 2:37 PM, That One Guy /sarcasm < [email protected]> wrote: > is your syncinjector providing sync reliably? Ours were dropping sync alot > from the injector, with hld off time it wasnt impacting, but I switched to > gps sync anyway > > On Tue, Dec 15, 2015 at 1:31 PM, Josh Luthman <[email protected] > > wrote: > >> My main site is 8x ePMP 24v with SynInjectors. I'm doing 24v but the >> distance from the SyncInjector to radio is tops 60 feet of cat5. >> >> 20v is when they won't boot. >> >> If your runs are 100-200 feet I doubt you'll lose 3.5 volts. I'm not >> sure what kind of amperage capacity the 750p has, though. >> >> Josh Luthman >> Office: 937-552-2340 >> Direct: 937-552-2343 >> 1100 Wayne St >> Suite 1337 >> Troy, OH 45373 >> >> On Tue, Dec 15, 2015 at 2:28 PM, Christopher Gray < >> [email protected]> wrote: >> >>> The spec sheet shows ePMP sync radios accept supplies as low as 23V. >>> >>> I am currently running 24V systems with ePMP non-sync radios. Does >>> anyone run 24V systems with ePMP sync radios? My Mikrotik 750UP and 750P >>> outputs measure only 23.5V, so I'd expect very little room for losses. >>> >>> I want to try some, but I don't want to change my power configuration >>> just yet if I don't have to. >>> >>> Thanks - Chris >>> >> >> > > > -- > If you only see yourself as part of the team but you don't see your team > as part of yourself you have already failed as part of the team. >