is your syncinjector providing sync reliably? Ours were dropping sync alot from the injector, with hld off time it wasnt impacting, but I switched to gps sync anyway
On Tue, Dec 15, 2015 at 1:31 PM, Josh Luthman <[email protected]> wrote: > My main site is 8x ePMP 24v with SynInjectors. I'm doing 24v but the > distance from the SyncInjector to radio is tops 60 feet of cat5. > > 20v is when they won't boot. > > If your runs are 100-200 feet I doubt you'll lose 3.5 volts. I'm not sure > what kind of amperage capacity the 750p has, though. > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > > On Tue, Dec 15, 2015 at 2:28 PM, Christopher Gray < > [email protected]> wrote: > >> The spec sheet shows ePMP sync radios accept supplies as low as 23V. >> >> I am currently running 24V systems with ePMP non-sync radios. Does anyone >> run 24V systems with ePMP sync radios? My Mikrotik 750UP and 750P outputs >> measure only 23.5V, so I'd expect very little room for losses. >> >> I want to try some, but I don't want to change my power configuration >> just yet if I don't have to. >> >> Thanks - Chris >> > > -- If you only see yourself as part of the team but you don't see your team as part of yourself you have already failed as part of the team.