If there is a grounding problem or induced voltage problem the surge suppressor 
will do its job and clamp the data lines to ground.  Have seen this many times. 
 Fix the ground loop and everything starts to work.  

From: George Skorup 
Sent: Friday, April 29, 2016 12:00 PM
To: [email protected] 
Subject: Re: [AFMUG] Gigabit Ethernet on Cambium 450i

Are you absolutely sure it's a GIGE-APC-HV? Should be printed GIGE-APC on the 
board and then they write HV on the back side of the handle.

I have gigabit running through lots of them and they work fine. But now that I 
think about it, those are only AirFiber's and licensed radios. No 450 APs doing 
GigE + sync-over-power yet.


On 4/29/2016 11:03 AM, Wireless Administrator wrote:

  We�re not able to get our Cambium 450i radio�s Ethernet Interface to run 
at Gigabit speed.� 
  Our setup is as follows:
  Gigabit switch (Tried several brands) �14� Cat6 Patch �Gigabit Sync 
injector (48V) � 35� Best-tronics Cat5 Shielded � 800-800-GIGE-APC-HV � 
80� Best-tronics Cat5 Shielded � Cambium 450i
  It works without the 800-800-GIGE-APC-HV. (Cat5 Coupler).
  Anyone ���.
  �
  Steve B.
  �
  �
  �


Reply via email to