At 48 volts, and .75 amps per pair of power wires, that would be 36
watts + 36 watts, or 72 watts total?
Just noodling here.
bp
<part15sbs{at}gmail{dot}com>
On 11/14/2016 11:38 AM, George Skorup wrote:
For the record,
http://store.packetflux.com/powerinjector-plus-sync-gigabit-version/
says: 1A per port maximum power. (48 watts at 48 Volts)
So.. is the electronic over-current protection the 1A limit? Or is
this just outdated info? Pretty sure it's >1A because I've "tested" it
(cable leaking water into the GigE-APC, the port didn't trip, and the
card was hot as hell).
I was also unaware that Cambium won't be supporting sync-over-power on
the 450m. I imagine the ringing/bounce issue killed that idea due to
the high power consumption.
On 11/14/2016 1:00 PM, Forrest Christian (List Account) wrote:
The current products should power the 450M just fine. The rating is
1A per pair per port, so at the 48V you're good up to 96W.
On Nov 14, 2016 7:50 PM, "George Skorup" <[email protected]
<mailto:[email protected]>> wrote:
The 450m pulls 70 watts. The current
SyncInjector/PowerInjector+Sync is around 1A max per port. What
you could do for now is a GigE-POE-APC and the new aux port
version SyncBox Junior.
On 11/14/2016 12:34 PM, Matt wrote:
Shouldn't the sync over power for the 450M be the same as
PMP450i?
How is the 1u sync injector coming?
On Mon, Nov 14, 2016 at 12:30 PM, Forrest Christian (List
Account)
<[email protected] <mailto:[email protected]>> wrote:
All of the currently shipping syncbox product line are
compatible. For sync
over power, I have the specs, but the design isn't done yet.
On Nov 14, 2016 5:40 PM, "Sam Lambie"
<[email protected] <mailto:[email protected]>> wrote:
A question for Forrest mostly. Have you come up with
a timing product for
the 450m AP yet? If not, have you got a timeline for
release?
Sam
--
--
Sam Lambie
Taosnet Wireless Tech.
575-758-7598 <tel:575-758-7598> Office
www.Taosnet.com <http://www.Taosnet.com>