Load impedance changes constantly while booting.  It levels out after booted 
up.  The real data I posted yesterday I did exactly that.  I added 8 ohms and 
it quit working down in the 15 volt range.  It was below 11 volts on the SM.  

So 6 watts/11 volts  =   .545 ohms.  

From: Forrest Christian (List Account) 
Sent: Saturday, March 11, 2017 4:50 PM
To: af 
Subject: Re: [AFMUG] So anti-climatic

So, here's my question (which I would play with on the bench if I was at 
home)....


Take a radio (such as a 100 series cambium) that is known to run down to below 
12V....


Put 29Vdc into the circuit.  Add series resistance until the sqrt(4RP) term 
reaches zero.   This should be about 14.5vdc.   


Now what happens?   I mean in real life, not in the math world.


I'm almost 100% certain this has to do with the whole maximum power transfer 
theorem which is discussed in electronics courses.   That is, the maximum power 
you can transfer is at the point where the impedance of the power source 
matches the impedance of the load.   Since the math states that the point where 
the sqrt(4rp) term reaches zero you're at 50% of the input voltage at the 
output, then it would lead to the conclusion that the effective impedance of 
the power source matches the impedance of the load since this would result in a 
50/50 voltage division at this point.


Since increasing the impedance of the power source beyond this point will 
result in a decrease in the power available to the load, it would follow that a 
constant power load would no longer work beyond this point - that is, below the 
50/50 point you end up with the load not being able to extract enough power 
from the line to work at all. 


On Sat, Mar 11, 2017 at 12:35 PM, <[email protected]> wrote:

  This is what I was looking for when I started this quest.

  The formula is so simplistic, it almost seems like for the amount of work I 
put into it it should be more complex.

  If you cannot see the image, there is the bottom line.

  If you have a device that uses a switch mode regulator, which is many things 
these days because the are efficient, cheap and small, you have a device that 
is essentially a constant power load.

  If you have to power that constant power load, (like an SM or a VDSL ethernet 
line extender) over wires that have a significant amount of resistance, like 
1000 feet of 24 gauge twisted pair, there is a lower voltage beyond which they 
will not operate.  (I would say to not exceed their input voltage either 
without zener protection).

  That voltage is:

  V(supply min) = 2 sqrt(PR)

  Where P is the power of the load.
  R is the power wire resistance.

  In my case, I need 48.99 volts or more.





-- 

      Forrest Christian CEO, PacketFlux Technologies, Inc.

      Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602
      [email protected] | http://www.packetflux.com

         