I agree Adam though Cat 6 is designed for greater immunity from cross talk between the pairs which I suppose will give it some extra overhead when alien cross talk is present. Here is what Mimosa says, "Most Ethernet problems we see are related to cabling. The 1000BaseT standard is far more sensitive to coupled noise than 100BaseT, which is why we highlight in our documentation that shielded CAT6 is required for reliable operation."

http://backhaul.help.mimosa.co/backhaul-troubleshooting-guide-ethernet

Adam Moffett wrote:
Cat 5e and Cat6 are both intended to run GigE at 100 meters. Did they elaborate on why that would make a difference? I would question them on that before I start sending climbers up, but I'm an a**hole.


------ Original Message ------
From: "Jay Weekley" <[email protected]>
To: "[email protected]" <[email protected]>
Sent: 6/7/2017 10:24:27 AM
Subject: [AFMUG] Shielded Cat6 recommendation

We recently received a recommendation from Mimosa to replace our shielded Cat 5 with Cat6. We've been using Shireen lately and they have a Cat 6 product. What would you use? Has anyone had problems with using Cat 5 with Mimosa?


---
This email has been checked for viruses by AVG.
http://www.avg.com



Reply via email to