Same results for sequence errors either with or without flow control
enabled on the radios, and switch ports that connect to them.



On Mon, Jan 15, 2018 at 9:23 AM, Colin Stanners <cstann...@gmail.com> wrote:

> What are the flow control settings? I remember seeing a graph that flow
> control has a big effect on whether AirFibers can hit near the full speed.
>
> On Mon, Jan 15, 2018 at 11:13 AM, Eric Kuhnke <eric.kuh...@gmail.com>
> wrote:
>
>> Hey Ubiquiti people who might be watching the list,
>>
>> If you're watching the list, please contact me...  I have an AF24 link
>> with "perfect" RF characteristics that won't pass a 500 Mbps full duplex
>> RFC2544 test. It also fails MEF y.1731 tests at the same data rate.
>>
>> 1.70 km, -55 RSL symmetric on both sides, radios report 774 Mbps capacity
>> full duplex.
>>
>> We have already replaced a radio on one end, the data cables, tried
>> bypassing surge protectors, and replaced cables.
>>
>> This link performs normally with 0.00% packet loss and full duplex layer
>> 3 IP traffic. Between Adva metro Ethernet equipment we can't get a 500 Mbps
>> test to run cleanly.
>>
>
>

Reply via email to