You could try turning off inband mangement if you have not already done so.

On Mon, Jan 15, 2018 at 11:27 AM, Eric Kuhnke <eric.kuh...@gmail.com> wrote:

> Same results for sequence errors either with or without flow control
> enabled on the radios, and switch ports that connect to them.
>
>
>
> On Mon, Jan 15, 2018 at 9:23 AM, Colin Stanners <cstann...@gmail.com>
> wrote:
>
>> What are the flow control settings? I remember seeing a graph that flow
>> control has a big effect on whether AirFibers can hit near the full speed.
>>
>> On Mon, Jan 15, 2018 at 11:13 AM, Eric Kuhnke <eric.kuh...@gmail.com>
>> wrote:
>>
>>> Hey Ubiquiti people who might be watching the list,
>>>
>>> If you're watching the list, please contact me...  I have an AF24 link
>>> with "perfect" RF characteristics that won't pass a 500 Mbps full duplex
>>> RFC2544 test. It also fails MEF y.1731 tests at the same data rate.
>>>
>>> 1.70 km, -55 RSL symmetric on both sides, radios report 774 Mbps
>>> capacity full duplex.
>>>
>>> We have already replaced a radio on one end, the data cables, tried
>>> bypassing surge protectors, and replaced cables.
>>>
>>> This link performs normally with 0.00% packet loss and full duplex layer
>>> 3 IP traffic. Between Adva metro Ethernet equipment we can't get a 500 Mbps
>>> test to run cleanly.
>>>
>>
>>
>

Reply via email to