It's probably 20-30 feet of cat5 at the most.  I've been doing 24v since
day one and it's gone through a couple of winters now.  Thing is that we
don't reboot when it's 5* and the batteries are all inside on the ground.

Chuck...would epmp have problems here rebooting/not powering for a few
minutes with bad SS cards?


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Mon, Apr 30, 2018 at 1:50 PM, Steve Jones <[email protected]>
wrote:

> IIRC the issues are connected if the surge suppressors are in line. I dont
> recall if the ones we had that were rebooting were resolved with just the
> port speed or bypassing.
> Using 48 v makes sure the EPMP doesnt freeze, they will with the 24, and
> if its long runs the power drop may be an issue too
>
> On Mon, Apr 30, 2018 at 12:42 PM, Josh Luthman <
> [email protected]> wrote:
>
>> No ethernet problems - it's POWER.
>>
>>
>> Josh Luthman
>> Office: 937-552-2340
>> Direct: 937-552-2343
>> 1100 Wayne St
>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>> Suite 1337
>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>> Troy, OH 45373
>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>>
>> On Mon, Apr 30, 2018 at 1:35 PM, Steve Jones <[email protected]>
>> wrote:
>>
>>> If you have the old MT surge suppressors with EPMP there was an issue
>>> with this and negotiation. I believe current revisions have resolved it.
>>> Also, if you are only running 20mhz channels you dont need gigabit
>>> connectivity, so you can lock ports to 100mbps to help
>>>
>>> On Mon, Apr 30, 2018 at 12:16 PM, Josh Luthman <
>>> [email protected]> wrote:
>>>
>>>> I've got two of these with problems: http://store.packetf
>>>> lux.com/powerinjector-plus-sync-gigabit-version/
>>>>
>>>> However one of these gives me no problems: http://store.packetf
>>>> lux.com/sitemonitor-4-channel-gigabit-poe-injector-controller/
>>>>
>>>> I have a 24vdc plant going up the tower.  In the box it feeds these
>>>> three Packetflux units.  The 4 channel POE injector has given me 0 
>>>> problems.
>>>>
>>>> I've got Cambium ePMP on the PowerInjector and it has been randomly?
>>>> rebooting units for several months.  Yesterday one of the ports just
>>>> decided to turn off for 20 minutes and come right back.  We've replaced the
>>>> line & radio to make sure it's the box, but all signs point to it.
>>>>
>>>> Has anyone else seen this or am I lucky in getting the only two units
>>>> with power problems on them?  AFAIK sync has been just as reliable as the
>>>> power through them.
>>>>
>>>> Josh Luthman
>>>> Office: 937-552-2340
>>>> Direct: 937-552-2343
>>>> 1100 Wayne St
>>>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>>>> Suite 1337
>>>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>>>> Troy, OH 45373
>>>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>>>>
>>>
>>>
>>
>

Reply via email to