> The delay was exactly the problem--Neither mtx nor the chg-zd-mtx script
> allowed for a delay between unloading one tape and loading the next one,
> and the changer did not like this. I editted the chg-zd-mtx script and
> put in a "sleep 30" command (may increase that value to be on the safe
> side) and that seems to have fixed the problem.
Ugh, what a horrible solution. My update to chg-zd-mtx actually looks at
"mt status" and goes on when the drive is ready.
For any interested parties, I haven't finalized the update because I'm
tracking a weird problem where the drive never comes online. It's hard to
trace because it only happens every 2 weeks right now. I'm guessing that
it's related to the HP's ability to clean itself on demand, which is hard
to replicate for testing ;( I'll get it out soon.
--
Joe Rhett Chief Technology Officer
[EMAIL PROTECTED] ISite Services, Inc.
PGP keys and contact information: http://www.noc.isite.net/Staff/