From: "Abe Kornelis" <[email protected]> Sent: Sunday, September 24, 2017 12:25 AM
In the new PoO (Publication SA22-7832-11) I noticed that opcode B93C has changed it's mnemonic from PPNO to PRNO - probably to reflect it's new ability to perform True Random-Number Generation. For compatibility the PPNO mnemonic is still mentioned in the instruction's description. Nevertheless, the PPNO mnemonic has disappeared from the appendix B. This holds for figures B-1, B-2, and B-3. Isn't it strange that a supported mnemonic is omitted from the appendix? Or was the PPNO mnemonic inadvertently maintained in the instruction description?
It seems likely that PRNO is a better mnemonic, and that the old one PPNO is being phased out. --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus