Hi John,

 

I saw your post about fitting oxygen to a Mosquito. Since I did this 2 years
ago, I though I should respond. Don't know if you already have the bottle
fitted to the aircraft and therefore need only to fit the regulator and EDS
system. But in case you also need a bottle, the following may help.

 

I purchased a 300 mm diameter bottle from MH hoping that I might be able to
use the Oxygen retaining system in the Mosi which has a neck clamp, an
aperture in the rearmost bulkhead and a retaining ring suspended further
down the fuselage. The retaining ring has a hole with a diameter slightly
greater than 300 mm and that bottle was long enough.

 

However, the MH bottle is not compatible with the neck clamp. This neck
clamp has a bar that fits across the bulkhead opening with retaining screws
at either end that locate into the bulkhead, and a removable saddle clamp.
There is an aperture through both to locate and hold the neck. I don't know,
but maybe this fitting is for "European" design bottles. I believe there is
a difference between US and other bottles. It may pay to investigate the
neck design of European bottles to see if you can use the existing retaining
system. These bottles should still be compatible with the MH regulator and
EDS system.

 

Having bought the US bottle, my solution was to make a "bucket" to fit into
the fuselage. It was a fiberglass tube with a closed end and a flange at the
bulkhead end. The flange secured to the bulkhead (four nuts on the flange)
and the suspended ring down the fuselage was enlarged slightly so the tube
located through it. A cap was then made that fitted over the shoulder of the
bottle with a hole big enough to locate over the valve and regulator. The
cap is secured to the bulkhead by two bolts with wing nut ends and has felt
that locates against the bottle. The bottle is placed in a nylon mesh bag
(orange bag) prior to sliding into the tube to protect the outer surface of
the bottle. This securely holds the bottle, but it is still easy to remove
for refilling. Mark Morgan did the entire job; fiberglass and fitting work,
so you could also contact him.

 

There are a number of members in our club now using the MH EDS system. It
works well and is very easy to use. I would recommend it.

 

Hope this helps.

 

Craig Vinall

 

 

  _____  

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Ashford,
John
Sent: Monday, 2 June 2008 6:12 AM
To: [email protected]
Subject: [Aus-soaring] FW: Mountain High Oxygen.

 

I'm about to purchase a Mountain High oxygen system for the mosquito.  Does
anyone have any advice on purchase or configuration of the system?

regards

 <http://thewell.santos.com.au/teamlink/directory/moreinfo.asp?strEntID=836>
John Ashford 

Maintenance Supervisor, Dullingari / Cross Border

Santos Ltd

PO Box 1010

Bne 4001

Ph  08 8678 4751

Fax 08 8678 4740





 Santos Logo <http://www.santos.com/library/logo.gif> 


Santos Ltd A.B.N. 80 007 550 923


Disclaimer: The information contained in this email is intended only for the
use of the person(s) to whom it is addressed and may be confidential or
contain privileged information. 

If you are not the intended recipient you are hereby notified that any
perusal, use, distribution, copying or disclosure is strictly prohibited. 

If you have received this email in error please immediately advise us by
return email and delete the email without making a copy.

Please consider the environment before printing this email


_______________________________________________
Aus-soaring mailing list
[email protected]
To check or change subscription details, visit:
http://lists.internode.on.net/mailman/listinfo/aus-soaring

Reply via email to