On Wed, 07 Jan 2009 16:20:10 GMT, Brian on Harnser
<[email protected]> wrote:

>Bruce Napier formulated on Wednesday :
>> I'm about to replace my 5 litre accumulator tank in the fresh water  
>> system. The new one came pre-pressured to 5 bar. Since my ParMax 3  
>> cycles between 1.4 and 2.8 bar, I guess I need to reduce the tank  
>> pressure to something between those two values.
>>
>> Anyone got any advice about the optimum, or do I just do it by trial  
>> and error until I get an acceptable delay before the pump comes in?
>>
>between 2 and 2.25 bar should work OK

Sorry but I disagree!

To set the accumulator pressure do the following.
Turn off your pump at the electrical supply
Open a tap to allow system pressure to be zero
Pump up or let down the accumulator until the pressure is
approximately half of the pump pressure-switch trip setting.

Close tap, re-enable electrical supply. 
Test pressure yearly under conditions described above.

--
Richard