Kapil is correct as far as CAS MGCP circuits go.
I am sorry - but I was under the impression that you were strictly
asking about a PRI config with MGCP.
If you wanted two PRI timeslots - one used in outbound and one used in
inbound only direction - set them both up as h323 (i.e. two pri-
timeslot commands without the 'service mgcp' at the end). H323 can
handle that problem all day long with no issues (bugs or otherwise).
Cheers,
--
Mark Snow
CCIE #14073 (Voice, Security)
Senior Technical Instructor - IPexpert, Inc.
Telephone: +1.810.326.1444
Fax: +1.309.413.4097
Mailto: [EMAIL PROTECTED]
--
Join our free online support and peer group communities:
http://www.IPexpert.com/communities
--
IPexpert - The Global Leader in Self-Study, Classroom-Based, Video-On-
Demand and Audio Certification Training Tools for the Cisco CCIE R&S
Lab, CCIE Security Lab, CCIE Service Provider Lab , CCIE Voice Lab and
CCIE Storage Lab Certifications.
--
On Oct 30, 2008, at 2:53 AM, kapil atrish wrote:
When adding CAS circuit in CCM (MGCP) it gives option to enable
channels for Outbound/Inbound/Bothways. I never tried but won't that
work for us.
Secondly, if CAS circuit in H.323 mode you may create multiple DS0
and point DPs to respective voice-ports for outbound calls leaving
others for inbound.
Paul and Bobs <[EMAIL PROTECTED]> wrote:
Thanks for the reply. How can this this be achieved. I know from the
PABX world , you can control the number of outbound and inbound
channels and would love to find a way of doing this i the Cisco
world on either MGCP or H.323. Doesnt matter which one (both would
be good) but if not then just one of them.
Cheers
On Wed, Oct 29, 2008 at 11:02 PM, Mark Snow <[EMAIL PROTECTED]>
wrote:
No because you can't create two pri-group timeslot service mgcp
commands because then you would have to create two mgcp gateways in
CUCM and 4.1.3 won't allow you to do this to the same hostname.
Mark Snow
Sr Technical Instructor
IPexpert, Inc.
Sent from my iPhone
On Oct 28, 2008, at 11:36 PM, "Paul and Bobs"
<[EMAIL PROTECTED]> wrote:
Thanks Mark
If I wanted to just use mgcp, is there a way to control which
channels are used. So I can reserve 10 channeles for outgoing and
10 for incoming with a total of 20
On Wed, Oct 29, 2008 at 2:19 PM, Mark Snow <[EMAIL PROTECTED]>
wrote:
BTW - that's not to say that I recommend it - but for lab purposes
should be all good.
There could be bugs associated with it - and I would definitely
check BugNavigator before putting it into production :)
cheers,
--
Mark Snow
CCIE #14073 (Voice, Security)
Senior Technical Instructor - IPexpert, Inc.
Telephone: +1.810.326.1444
Fax: +1.309.413.4097
Mailto: [EMAIL PROTECTED]
--
Join our free online support and peer group communities:
http://www.IPexpert.com/communities
--
IPexpert - The Global Leader in Self-Study, Classroom-Based, Video-
On-Demand and Audio Certification Training Tools for the Cisco CCIE
R&S Lab, CCIE Security Lab, CCIE Service Provider Lab , CCIE Voice
Lab and CCIE Storage Lab Certifications.
--
On Oct 28, 2008, at 10:20 PM, Paul and Bobs wrote:
Hi All
I was wandering if anyone know of a way using both MGCP and H.323
to control the channells on an E1/T1 circuit. For example - If I
have a single E1 service with only 20 channels and I want to say
reserve 5 for outgoing and reserve 15 for incoming, is there a way
on both protocols to do this.
Thanks