Maybe your old solution evaporated then you end up in your old tube with a
more concentrated solution in PEG and NaCl so try to screen with new
conditions with higher PEG and/or NaCl concentration....

Mick

2011/4/12 Jun Yong Ha <j...@princeton.edu>

> Hi all,
>
> Recently, I produced crystals with MBClass1-64 which contains PEG4000,
> HEPES-Na and NaCl. But, I struggled to reproduce crystals. I tried to set up
> tray with different batch of solution. I got the crystals only from 2008
> solution, but not from fresh ones. I asked technical service of Qiagen, but
> they did not have any stock.
>
> pH between fresh and old solution is the same. I could reproduce crystals
> with this old solution 100% when setting up.
>
> Do you have any experience like this? Is PEG4000 degraded or oxidized?
>
> Please help me.
>
> Thanks in advance.
>



-- 
------------------------------------------
Mickael Blaise PhD
Department of molecular biology
Centre for structural biology
Aarhus university
Gustav wieds vej 10
8000 Aarhus-Denmark

Reply via email to