On Thu, Jul 24, 2003 at 04:10:39AM -0800, Elbert Smit wrote:

> > Where abouts are you applying the ESD? (case, window etc.?)
> 
> Metal part of the housing, no earthing available. 

Are all metallic parts (of the housing and other parts) connected together?
If not you will have some sparks at overlapping positions and more problems...

>- The metal part is connected to the ground layer of the PCB

Is there one connection or more than one? You can have currents through
the PCB layer that create high voltages in other wires...

>- The PCB contains a transzorb like component (one direction)
 
Is it fast enough? Maybe 10�s are too slow. 

        Matthias
-- 
Author: Matthias Weingart
  INET: [EMAIL PROTECTED]

Fat City Network Services    -- 858-538-5051 http://www.fatcity.com
San Diego, California        -- Mailing list and web hosting services
---------------------------------------------------------------------
To REMOVE yourself from this mailing list, send an E-Mail message
to: [EMAIL PROTECTED] (note EXACT spelling of 'ListGuru') and in
the message BODY, include a line containing: UNSUB CHIPDIR-L
(or the name of mailing list you want to be removed from).  You may
also send the HELP command for other information (like subscribing).

Reply via email to