On Mon, Aug 07, 2017 at 05:07:45PM +0000, Jahagirdar, Bhushan wrote:
> MS Name/IP address         Stratum Poll Reach LastRx Last sample
> ===============================================================================
> #? GPS                           0   2   377     2   -4509h[ -4509h] +/-  
> 6567m
> #? CAN                           0   2     0     -     +0ns[   +0ns] +/-    
> 0ns

The error of +/- 6567 minutes is probably what causes chronyd to
ignore the source. The offset of the reference time may be jumping
around. What is on the other side of the socket? Is it gpsd?

You could enable the refclocks log to see what values is chronyd
getting.

-- 
Miroslav Lichvar

-- 