On Mon, Aug 07, 2017 at 05:07:45PM +0000, Jahagirdar, Bhushan wrote: > MS Name/IP address Stratum Poll Reach LastRx Last sample > =============================================================================== > #? GPS 0 2 377 2 -4509h[ -4509h] +/- > 6567m > #? CAN 0 2 0 - +0ns[ +0ns] +/- > 0ns
The error of +/- 6567 minutes is probably what causes chronyd to ignore the source. The offset of the reference time may be jumping around. What is on the other side of the socket? Is it gpsd? You could enable the refclocks log to see what values is chronyd getting. -- Miroslav Lichvar -- To unsubscribe email chrony-users-requ...@chrony.tuxfamily.org with "unsubscribe" in the subject. For help email chrony-users-requ...@chrony.tuxfamily.org with "help" in the subject. Trouble? Email listmas...@chrony.tuxfamily.org.