Hi, What is the output from 'show controllers errors fabric'? First of all I would try to reseat the LC6 and see if the CRC errors stop.
-----Mensagem original----- De: [email protected] [mailto:[email protected]] Em nome de Antonio Soares Enviada em: segunda-feira, 16 de novembro de 2009 10:15 Para: [email protected] Assunto: [c-nsp] FABRIC-3-ERR_HANDLE Hello group, I have a 12k reporting this: %FABRIC-3-ERR_HANDLE: Reconfigure LC on fabric due to CRC error from slot 6 In one week, i have 4 of these messages. Slot 6 is a SIP-601 containing 2 x SPA-10G. What could be the problem ? The "show controllers fia" do not show any problem. The "execute-on slot 6 show controllers fia" show this: Switch cards present: 0x1F Switch cards monitored: 0x1F 0 1 2 3 4 -------- -------- -------- -------- -------- los 0 0 0 0 0 state Off Off Off Off Off crc16 53989 0 0 0 0 xor error0 0 0 0 cell drops1020 1020 1020 1020 IOS=c12kprp-p-mz.120-32.SY6.bin Thanks. Regards, Antonio Soares, CCIE #18473 (R&S) [email protected] _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/