Had the same problem a few years ago. Was solved using a separate vlan for each switch (we had 3500XL CPE) Scale to a few hundred CPE switches Support for ip unnumbered from SXF
6500 Int vl 100 Ip add 10.10.10.1 255.255.255.0 Int vlan 200 Desc CPE switch 1 Ip unnumbered vlan 100 Ip local proxy-arp (ip proxy-arp local??) Int vlan 201 Desc CPE switch 2 Ip unnumbered vlan 100 Ip local proxy-arp (ip proxy-arp local??) 3750 Use ordinary private vlan config, using separate vlan on each switch Jon Harald Bøvre -----Opprinnelig melding----- Fra: [email protected] [mailto:[email protected]] På vegne av Erik Witkop Sendt: 9. juli 2010 14:35 Til: [email protected] Emne: [c-nsp] pvlan (Private Vlan) setup question So I have two 3750 (no stackwise) that uplink to a 6509. I have setup pvlans on both 3750's and they are working as expected. I cannot ping servers on the same 3750 switch. But of course if the servers try to communicate with another server on the OTHER 3750 switch, the ping is successful (traveling via the uplink to distribution). I know that pvlans only work local to the switch it is configured on. So I need a way to block that 3750-to-3750 communication on the distribution layer. My distribution switch is a 6509 (sup720). I was hoping to see if I could use 'switchport protected' as a quick one liner so that each downlink to the 3750's would not be able to communicate. But that is only on the 3550, I think. Any ideas? 3750 config: ! vlan 666 name isolated-vlan private-vlan isolated ! vlan 810 name promiscous-vlan private-vlan primary private-vlan association 666 ! interface GigabitEthernet2/0/30 description xxxxxxx switchport private-vlan host-association 810 666 switchport mode private-vlan host spanning-tree portfast ! interface GigabitEthernet2/0/31 description xxxxxxx switchport private-vlan host-association 810 666 switchport mode private-vlan host spanning-tree portfast ! interface TenGigabitEthernet2/0/1 description Uplink to 6509 switchport private-vlan mapping 810 666 switchport mode private-vlan promiscuous speed nonegotiate spanning-tree guard loop Now if I use pvlans on the 6509, those downlinks would have to be promiscous ports I think. And that probably would achieve the 3750-3750 blocking that I want. Any thoughts? p.s. I would rather not use VACL's as that could get administratively tiring. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/