On Fri, Jul 9, 2010 at 8:29 AM, Erik Witkop <[email protected]> wrote:
> Thanks John. > > That seems viable. My only concern is if I have more and more customers > coming into distribution, the config could get hairy. > > I was hoping I could make a different isolated vlan on the second 3750 > switch. And then I was hoping that a ping from isolated vlan to isolated > vlan from switch to switch would fail. > But I was wrong, it is somehow pinging even after I changed the isolated > vlan on the second 3750 from 666 to 667. > > Am I wrong is thinking that it should not ping? If you don't tag between the distribution and access layer, you can pass pvlans around (as the only VLAN on the cable) but you have to do it non-redundantly. On the other hand, if you tag between the access and distribution layer, you can carry the pvlan (and other VLANs) on the same cable and include redundant uplinks. Sample: distribution2: vlan 101 name backups-primary private-vlan primary private-vlan association 102 ! vlan 102 name backups-isolated private-vlan isolated ! interface GigabitEthernet1/1 description distribution1 switchport switchport trunk encapsulation dot1q ! interface GigabitEthernet1/2 description access1 switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 101,102 distribution1: vlan 101 name backups-primary private-vlan primary private-vlan association 102 ! vlan 102 name backups-isolated private-vlan isolated ! interface GigabitEthernet1/1 description distribution2 switchport switchport trunk encapsulation dot1q ! interface GigabitEthernet1/2 description access1 switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 101,102 access1: vlan 101 name backups-primary private-vlan primary private-vlan association 102 ! vlan 102 name backups-isolated private-vlan isolated ! interface GigabitEthernet1/1 description distribution1 uplink switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 101,102 ! interface GigabitEthernet1/2 description distribution2 uplink switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 101,102 ! interface GigabitEthernet1/3 description server1 switchport switchport private-vlan host-association 101 102 switchport mode private-vlan host no ip address spanning-tree portfast With this configuration, you can connect any number of access switches to your distribution switches and the pvlan you have created will properly enforce communication rules between "host" or "promiscuous" ports connected to any switch within the network. I use this heavily for providing secure backups to thousands of servers throughout my datacenters. Servers can connect their backups NIC to any port on any switch and we simply set the pvlan on that port. The server will then only be able to communicate with the promiscuous ports (which also can be located anywhere within the network). Typically a network consists of ~20 access switches plus 2 distribution switches. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/