hi Brian, So what you're saying is that in the SIP dial rule; I'll click the "Add Plar" button and then give my parameter a description, select "Button" as my dial parameter then in the value box I'd enter a "1" or a "2" depending on if I wanted the *PLAR* working on line 1 or 2 of the ATA.
I would then assume that if I wanted both ATA lines to plar, I would have two parameters in the SIP dial rule? Oyyyy ..... I wish you would write Cisco docs .... I can understand you, lol. On Fri, Mar 13, 2015 at 3:38 PM, Brian Meade <[email protected]> wrote: > For the SIP Dial Rule, all you want it to have is a PLAR with Button 1 > set. Don't enter the number you want to PLAR to. Then just set up PLAR > like you would for a SCCP phone with a new CSS/partition/blank translation > pattern. > > On Fri, Mar 13, 2015 at 3:30 PM, Barry Howser <[email protected]> > wrote: > >> Hello everyone. >> >> I have an ATA190 that needs to do a plar to 911. My dial plan uses "9" to >> access an outside line (including the 911 pattern). >> >> I created a SIP dial rule and added a plar pattern. I added a parameter >> called "911" in the description and then added 9911 in the value field. I >> saved, applied config and restarted. >> >> I have applied that SIP Dial Rule to the ATA190 device's sip dial rule >> section and reset the ATA. When I take either of the lines off hook with an >> analog phone, I just get dial tone .... no PLARing. >> >> What am I doing wrong? >> >> thanks >> >> _______________________________________________ >> cisco-voip mailing list >> [email protected] >> https://puck.nether.net/mailman/listinfo/cisco-voip >> >> >
_______________________________________________ cisco-voip mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-voip