Ercoupe Bulliten No.15 addresses this issue, I think - also Kim Flora's
comments.
Refers to the overflow line failure inside the tank, making the center
tank
fuel level too low ---- and how to correct ..

Points out that the overflow line can be adjusted 

Feul level shouold be betweeen 3/4 and 1" from the  ---After filling the
fuselage tank full, and letting it drain through the overflow,   " At this
tim
ethe fuel level should be between 3/4" and 1 " below the bottom of the
fuselage tank filler neck when measured from the rearmost part". " The
level
may be corrected by relocating the overflow line after loosening the union
nut
on the mounting flange and moving the line up or down as required to
obtain
the proper level.

"A failure of the subject part would probably result in an immediate
forced
landing".


This bulliten afffected Sn 2623 - 2994  - Ercoupe part # 415-48162. 

Be happy to fax copy of bulletin - or better yet get yourself a copy of
all
servcice bulletins from Univar or Skyport.

Fly safe - Have Fun

Harry
93530

BCB

<<attachment: winmail.dat>>