On 02/04/2018 11:02 AM, Frank Scheiner wrote:
> since some recent package upgrades, login via serial console no longer works 
> for me on my T1000 (and also T5220, with same disk). Logins via SSH are 
> possible
> though (on T1000, the T5220 is still missing the correct network 
> configuration in `/etc/network/interfaces`, so no luck there with SSH).

Most likely a fallout of the binutils bug which generated broken code.

Try:

# wget 
http://ftp.ports.debian.org/debian-ports/pool-sparc64/main/g/gcc-7/libstdc++6_7.3.0-1+b1_sparc64.deb
http://ftp.ports.debian.org/debian-ports/pool-sparc64/main/g/gcc-7/gcc-7-base_7.3.0-1+b1_sparc64.deb
 && dpkg -i --force-depends
gcc-7-base_7.3.0-1+b1_sparc64.deb libstdc++6_7.3.0-1+b1_sparc64.deb

Then just run "apt update && apt -f install".

Adrian

-- 
 .''`.  John Paul Adrian Glaubitz
: :' :  Debian Developer - glaub...@debian.org
`. `'   Freie Universitaet Berlin - glaub...@physik.fu-berlin.de
  `-    GPG: 62FF 8A75 84E0 2956 9546  0006 7426 3B37 F5B5 F913