I have been running 100w output using AFSK A in the RTTY contest and I have 
been monitoring my PA temp via the meter. I have my fan set for FN2 constantly 
on, and the temp has only reached 45C.


Ken..G0ORH 

CW4EVER

Sent from my iPhone

     


On 24 Sep 2010, at 17:47, "Dave Hachadorian" <[email protected]> wrote:

> Here is a copy of a posting I made on 20090312:
> 
> Here is a copy of a posting I made on 20090312:
> 
> I did an experiment on my two K3's - key down at 100 watts
> for four minutes while noting PA Temp and fan speed. Both K3's 
> behaved
> identically and both leveled off at PA Temp = 64C after
> about 3 minutes. For the record, here are the results (best
> viewed with Courier font):
> 
> Time   Temp  Fan
> 0:00    26C   0
> 0:26    37    1
> 0:44    41    2
> 1:19    50    3
> 1:45    55    4
> 2:40    60    4
> 2:50    62    4
> 3:15    64    4
> 4:00    64    4
> 
> Room temp was 77F.
> 
> According to the manual, the PA is set to drop into bypass at
> 84C, so it didn't even come close.
> 
> Dave Hachadorian, K6LL
> Yuma, AZ
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> 
> . 
> 
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to