Before assuming that you have a problem, you should 1) Calibrate the K3 RF gain using the procedure built into the K3 Utility. 2) Calibrate the K3 s-meter using the procedure explained in the K3 manual. 3) Adjust the P3 calibration using the Amplitude Calibration procedure in the latest P3 manual.
You need a signal source like an XG1 or XG2 to do these steps accurately. On 1/16/2011 9:04 AM, Roy Morris wrote: > I have checked the calibration on both of my K3s with my XG-1, and the K3 S > meter is > miles apart from the P3 readings in S units. If this is going to be the case > especially in SSB, just please say thats the way it going to be. There are a > lot of us > apparently who are perplexed by these incongruent readings. If this is > normal, just > say so. Thanks. Roy Morris W4WFB > ______________________________________________________________ Elecraft > mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: > http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] > > This list hosted by: http://www.qsl.net Please help support this email list: > http://www.qsl.net/donate.html -- Vic, K2VCO Fresno CA http://www.qsl.net/k2vco/ ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html