On 09/29/2015 04:26 PM, Phil Hystad wrote:

The
bar graph registered an SWR of 3:1 (normally about 1.1:1) in
response to key down while in Test Mode.  Yet, the bar graph acts
normally showing the correct SWR in TX mode (not test).

In test mode there is no power out of the K3. The SWR calculation gets confused when both forward and reflected power are zero. In the next code release I'll add a feature to force the SWR to read 1:1 when forward power is close to zero.

Alan N1AL
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to