Trevor,
Make sure VOX is turned on for CW mode. See page 33 of the manual. The
Delay setting should control the amount of delay after each dit/dah or
if long enough it will not drop out until a significant time after
keying stops.
If your transverters use relays, I suggest that semi-breakin will work
better. If you need even more control for T/R switching the
transveters, use PTT.
73,
Don W3FPR
On 5/15/2017 9:20 AM, Trevor Clapp wrote:
When I am using the K3S with an external transverter which uses the key out
line to change from RX to TX i am finding that with a paddle input from my
Winkeyer I cannot get the transverter to remain keyed. Adjusting the CW delay
does not increase the time btween keying and the relay in the transverter
clicking out. So basically I get the relay clicking on every keyed letter.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]