"If you can figure out how to keep the relatively thin "Z" panel from expanding 
and contracting as it is heated and cooled, you will have a solution to the 
problem."


If the Z bracket really is the source of the noise, and I'm not yet convinced 
it is, then there is no need to stop it expanding and contracting. All that is 
needed is to change the mechanical interface between the Z bracket and whatever 
is binding and releasing to cause the clicks.


My plan was to put thin Mylar sheet between the Z bracket and the parts to 
which it is attached. I was going to start with the Z bracket to heat sink 
interface. I was not willing to do that until I had characterized the Z bracket 
temperature dynamics and understood the heat flow between the Z bracket and the 
heat sink. I have the data but no longer have the clicks.


73,

Andy k3wyc