hello Don, hello everyone, this morning I tested the K2 on my own.
the consumption (ampere) of K2 gave me part of the solution the K2 alone in transmission consumes 0.5 amp on 40M then on the other 2 amp bands with a setting at 5Watts so I have no broadcast on 40M only, we can hear the relays switch ... after I admit being a bit lost to know where to start I will review the soldering of relays K1, K12, K14 in case ... could you give me advice since you know the K2 very well Thanks in advance Don 73 ,F8ACF # K2 7369 - kpa 100 in progress Le ven. 10 avr. 2020 à 03:11, Don Wilhelm <[email protected]> a écrit : > > Christophe, > > I forgot to mention, > Before attempting to adjust the C1 null, first pre-set R26 and R27 to > 43k ohms. Measure R26 from U5 pin 5 to ground and R27 at U5 pin 3 to > ground. > > Then go through the nulling process followed by the power setting > process that I outlined in my prior email. > > 73, > Don W3FPR > > On 4/9/2020 3:25 PM, Christophe aufacf wrote: > > Good morning all , > > > > Zero adjustment of SWR bridge (C1) page 48 > > > > as you see on the video , I set the K2 to 5Watts > > > > https://we.tl/t-MOz5AX1v3l > > > > I managed to adjust the SWR the K2 announces my power at 0.1 Watts !! > > > > the consumption goes from 0.32 Amps in Rx, in Tune mode 0.5 amps > > > > I should have 5 Watts > > > > Thank you for your help > > > > # K2 7369 - kpa 100 in progress -- 73 , F8ACF56 ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]