Maybe they are more hungry out here in Oregon... They agreed and, (to
my great surprise), put it in the contract.
73, and thanks,
Dave (NK7Z)
https://www.nk7z.net
ARRL Volunteer Examiner
ARRL Technical Specialist
ARRL Asst. Director, NW Division, Technical Resources
On 5/27/20 9:14 AM, Gary wrote:
How did you find one that would agree to that? The 6 I've talked with all said
pass as soon as I brought the subject up....
73,
Gary kk0sd
-----Original Message-----
From: [email protected] <[email protected]> On
Behalf Of Dave Cole
Sent: Wednesday, May 27, 2020 8:45 AM
To: [email protected]
Subject: Re: [Elecraft] Quiet Ductless HVAC System
Hi Albert,
Here are a few suggestions... When I added my furnace, I made it part of the
purchase contract that there was to be no new RFI. This makes the vendor very
careful. Tell them it is a showstopper, and they will be responsible for RFI
removal if RFI comes with the new purchase. Get it in writing if possible.
Insist they call the manuafacturer and ask about RFI for the unit you are
considering, and are there RFI kits for that unit, PRIOR to your purchase...
Be careful assuming brand and model numbers will remain RFI quiet over time.
Vendors change parts, and circuits, within a fixed model number all the time...
What is RFI quiet today, may not be RFI quiet tomorrow...
Take measurements first, before the install, and after install. Use this
process:
https://www.nk7z.net/sdr-rfi-survey-p1/
It is part I of III in a series on using an SDR to model your RFI environment.
Perform the tests, save the results, then run them all again after install...
I run a full sweep once a year here, and keep the results... Also see my March
2020 article in CQ on this subject...
Good luck, and good for you for looking at this early!!!
73, and thanks,
Dave (NK7Z)
https://www.nk7z.net
ARRL Volunteer Examiner
ARRL Technical Specialist
ARRL Asst. Director, NW Division, Technical Resources
On 5/27/20 4:09 AM, Albert Reynolds wrote:
Does anyone have suggestions for an RF quiet ductless, also called a
"mini split" heat pump system. I am in need of a small (12000 BTU)
system for the ham shack. Comments from anyone who has used such a
system, or successfully mitigated RFI on a system would be
appreciated. Brand and model number would be highly appreciated.
Albert, N4AGG
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net Please help support this email
list: http://www.qsl.net/donate.html Message delivered to
[email protected]
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html Message
delivered to [email protected]
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]