Just to tie up loose ends, the problem is fixed, I took off the side panels, remove the coating where the springs contact, rearrange the the ribbon and power cable, tapped new threads in the heat sink, and fitted larger screws, now firmly seated. KR Andtew Andrew, If you only see the problem when the KPA100 is installed on the base K2, look at the wiring for the VRFDET line from the KPA100 to the K2. Broken wire or a pin not making proper contact with the K2 connector. This is a ribbon cable, but check for bad wires anyway - check at both ends of the cable. 73,Don W3FPR On 7/27/2026 5:38 PM, Andrew Lenton wrote:
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to