on 10/22/2006 Chris Radek wrote: >I don't have all the answers but your report led me to find a problem >with G92.3. I fixed it in both branches. I've found in my testing >with tkemc that if after the abort you issue G92.3, the program will >run in the same place again. If you do not issue the G92.3 the >program will run back at the origin, even though the same "Work >offset" is still shown in tkemc. > > Well, I'm still having a problem with this. I was using the TkEmc GUI, I don't know if the Axis GUI has the same symptoms.
Here's what I did: I set up X, Y and Z axes to align with part, using right mouse click over axis display. Run program to end, with M02 at end of program. (axes reset to original setting). Rerun program, and it has G92.3 in first block. This resets the coord system to the part's coords established previously. NOW, here's the rub : I need to reset the Z coordinate because I have removed and replaced the tool in the collet. When I do this, ALL the coords are reset! And, I haven't found a way to regain those settings. I am not sure this is due to an abort, or will occur after any M02 when you try to reset one axis. I should be able to change any coord. setting without disturbing the others. Does anyone know what is happening here? Does Axis do a better job of this? Thanks, Jon ------------------------------------------------------------------------- Take Surveys. Earn Cash. Influence the Future of IT Join SourceForge.net's Techsay panel and you'll get the chance to share your opinions on IT & business topics through brief surveys - and earn cash http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers