On 12 August 2015 at 11:27, Valerio Bellizzomi <[email protected]> wrote: > yes found it. StepConf asks for steps per revolution, I wrote 200.0 > there and it writes out the ini file with SCALE = 40.0
Is it direct-drive and no microstepping? In any event, the simple fix is to edit the INI to the right number. (but gearing and microstepping affect the "right" number". For direct drive and no microstepping the scale for degrees is 0.5555 but that gives you 1.8 degree steps and would be a strange way to configure a rotary axis. -- atp If you can't fix it, you don't own it. http://www.ifixit.com/Manifesto ------------------------------------------------------------------------------ _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers