John,
Maybe an ESD generator could help you find the problem. Playing with
the risetimes may get you an E-field in the 300-320 Mhz range..
Good luck!
Eric Petitpierre
Pulsecom
Herndon,VA
[email protected]
______________________________ Reply Separator _________________________________
Subject: Radiated Immunity
Author: [email protected] (John Juhasz) at smtp
List-Post: [email protected]
Date: 7/12/00 11:23 AM
Having a Radiated Immunity problem (300-320MHz - 3V/M ) that I need to
troubleshoot . . .
I don't have a screen room to work in . . . I want to troubleshoot down to
the circuit or component level . . .
is there any type of 'probe' that can be used instead of creating a
full-field in a chamber?
Any ideas . . . ? Haven't had a problem like this yet . . .
John Juhasz
Fiber Options
Bohemia, NY
631-419-2324
-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
To cancel your subscription, send mail to:
[email protected]
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Jim Bacher: [email protected]
Michael Garretson: [email protected]
For policy questions, send mail to:
Richard Nute: [email protected]