I recently completed a Brazilian compliance effort on a telecom device.

It was handled via a consultant with expertise in South American regulatory 
requirements.

I was required to supply copies of existing test reports ( Part 68, Part 15, 
applicable CTRs, and CB Scheme), electronic photos, and a description of the 
device and it's normal functionality.

No test samples or testing was required.  The information was reviewed and 
processed, and the end result was an ANATEL approval certificate.

If you'd like contact information for the Consultant I used, feel free to 
e-mail me.

At 05:04 PM 9/20/00 -0400, Clement Dave-LDC009 wrote:

>For Terminal Equipment the generic requirments are;
>
>Federal Official Gazette - Ordance No. 322 - Net No. 001/92
>
>There is also a test procedure - No.225-540-514 "Test Procedures for Data
>Communications Equipment for Transmission Nominal Speed Up yo 28800
>Bits/sec"
>
>These are published in Portuguese and you will need to have them translated.
>Make sure you get a technical translator. We had a requirement that got
>translated incorrectly that placed an out of band requirement on voice band
>signals.
>
>David Clement
>Motorola Inc.
>Global Homologation Engineering
>20 Cabot Blvd.
>Mansfield, MA 02048
>
>P: 508-261-4389
>F: 508-261-4777
>E: <mailto:[email protected]>
>
>Pager:
>Numeric: 978-545-5452
>Alpha: <mailto:[email protected]>
>
>
>
>-----Original Message-----
>From: [email protected] [mailto:[email protected]]
>Sent: Wednesday, September 20, 2000 1:43 PM
>To: [email protected]
>Subject: Brazilian requirements
>
>
>
>Group,
>
>Could you advise me on the Brazilian telecom requirements for interfaces to
>be connected to the analog PSTN?
>I was not able to find any information on this subject in English.
>
>Thank you in advance.
>
>John Radomski
>Product Compliance Engineer
>Clare Corp.
>
>
>-------------------------------------------
>This message is from the IEEE EMC Society Product Safety
>Technical Committee emc-pstc discussion list.
>
>To cancel your subscription, send mail to:
>      [email protected]
>with the single line:
>      unsubscribe emc-pstc
>
>For help, send mail to the list administrators:
>      Jim Bacher:              [email protected]
>      Michael Garretson:        [email protected]
>
>For policy questions, send mail to:
>      Richard Nute:           [email protected]
>
>
>-------------------------------------------
>This message is from the IEEE EMC Society Product Safety
>Technical Committee emc-pstc discussion list.
>
>To cancel your subscription, send mail to:
>      [email protected]
>with the single line:
>      unsubscribe emc-pstc
>
>For help, send mail to the list administrators:
>      Jim Bacher:              [email protected]
>      Michael Garretson:        [email protected]
>
>For policy questions, send mail to:
>      Richard Nute:           [email protected]
>

Jim Linehan
Hardware Engineer
VGSBU
Cisco Systems Inc.
300 Apollo Drive
Chelmsford, MA. 01824
Phone: (978) 244-5716
Fax:(978) 244-5908

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              [email protected]
     Michael Garretson:        [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]

Reply via email to