Dave, As I recall, this used to be in CISPR16 "...Radio Interference Measuring Apparatus and Methods," section 9. In later versions of CISPR16, this requirement was mysteriously deleted from CISPR16, and section 9 became "Reserved for future use." I have the old version of CISPR16 buried in my paper files somewhere. For ITE, CISPR16 was obsoleted by CISPR22.
The VCCI "audit" requirements per V-3/2000.04 were taken almost verbatim from this. Dan > Date: Mon, 12 Nov 2001 15:58:32 -0500 > From: David Heald <[email protected]> > X-Accept-Language: en > MIME-Version: 1.0 > To: "[email protected]" <[email protected]> > Subject: 80/80 rule for euro compliance? > Content-Transfer-Encoding: 7bit > X-Resent-To: Multiple Recipients <[email protected]> > X-Listname: emc-pstc > X-Info: Help requests to [email protected] > X-Info: [Un]Subscribe requests to [email protected] > X-Moderator-Address: [email protected] > > > Greetings all, > I remember hearing somewhere (& it seems that I found the answer > somewhere but I can't remember) that there is a stipulation for European > compliance that one should have 80% certainty that 80% of one's products > are compliant. I have no idea where this idea originally came from or > what standards it may apply to. > > Can anyone out there help me out? > > Dave > > ------------------------------------------- > This message is from the IEEE EMC Society Product Safety > Technical Committee emc-pstc discussion list. > > Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ > > To cancel your subscription, send mail to: > [email protected] > with the single line: > unsubscribe emc-pstc > > For help, send mail to the list administrators: > Michael Garretson: [email protected] > Dave Heald [email protected] > > For policy questions, send mail to: > Richard Nute: [email protected] > Jim Bacher: [email protected] > > All emc-pstc postings are archived and searchable on the web at: > No longer online until our new server is brought online and the old messages are imported into the new server. ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Michael Garretson: [email protected] Dave Heald [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: No longer online until our new server is brought online and the old messages are imported into the new server.