>-----Original Message-----
>From: Kim Boll Jensen [mailto:[email protected]]
>Sent: Thursday, February 12, 2004 3:13 AM
>To: EMC PSTC
>Subject: EN 55020 RF test
>
>
>
>Hi all
>
>In EN 55020 immunity to RF e.m. fields it is noted in 5.8.4 
>that for big
>equipment not fitting in the TEM, test as per EN 61000-4-3 is 
>permitted.
>
>My problem is that immunity test levels in EN 55020 is in 
>dB(uV/m) and EN
>61000-4-3 is in v/m. How do I convert ?
>
>Best regards,
>
>Kim Boll Jensen
>Bolls Rådgivning
>Ved Gadekæret 11F
>DK-3660 Stenløse





Kim:


For V/M to dBuV/M:


Multiply V/M time 1,000,000
Then take the Log (base 10)
Then multiply times 20
Example:
15 V/M
15,000,000 uV/M
7.176
143.5 dBuV/M


For dBuV/M to V/M:

Divide dBuV/M by 20
Then take the antilog
Then divide by 1,000,000
Example:
148 dBuV/M
7.4
25118864 uV/M
25.1 V/M


Ed

Ed Price 
[email protected]         WB6WSN 
NARTE Certified EMC Engineer & Technician 
Electromagnetic Compatibility Lab 
Cubic Defense Applications 
San Diego, CA  USA 
858-505-2780  (Voice) 
858-505-1583  (Fax) 
Military & Avionics EMC Is Our Specialty 



This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ieee-pses.org/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              [email protected]
     Dave Heald:               [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc

Reply via email to