I read in !emc-pstc that Kim Boll Jensen <[email protected]> wrote (in <[email protected]>) about 'EN 55020 RF test' on Thu, 12 Feb 2004:
>In EN 55020 immunity to RF e.m. fields it is noted in 5.8.4 that for big >equipment not fitting in the TEM, test as per EN 61000-4-3 is permitted. > >My problem is that immunity test levels in EN 55020 is in dB(uV/m) and >EN 61000-4-3 is in v/m. How do I convert ? 1 V/m is 120 dB(uV/m). -- Regards, John Woodgate, OOO - Own Opinions Only. The good news is that nothing is compulsory. The bad news is that everything is prohibited. http://www.jmwa.demon.co.uk Also see http://www.isce.org.uk This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ieee-pses.org/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc