Hi all In EN 55020 immunity to RF e.m. fields it is noted in 5.8.4 that for big equipment not fitting in the TEM, test as per EN 61000-4-3 is permitted.
My problem is that immunity test levels in EN 55020 is in dB(uV/m) and EN 61000-4-3 is in v/m. How do I convert ? Best regards, Kim Boll Jensen Bolls Rådgivning Ved Gadekæret 11F DK-3660 Stenløse Tlf.: 48 18 35 66 Fax: 48 18 35 30 Mobil: 22 99 69 91 E-mail: [email protected] web: www.bolls.dk This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ieee-pses.org/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc