At a lab where I used to work, there was a favorite saying "Nobody questions passing data". That was so true. If something failed, the first question the engineer would ask was "did you test it correctly".
There were many instances of an EUT being tested and failed by one technician, only to be sent back to the lab for another technician to test it, on a different shift, and it would pass. It may have failed by 2db, then pass by 1db. They always accepted the passing data. I could go on, but suffice to say I am now glad that I do not work there anymore. There was no reward for doing acurate testing, only in generating revenue. Bob Richards, NCT This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/listserv/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc