In message <ofa951a5e0.780aa02d-on862571db.002c2d8a-862571db.00314...@mmm.com>, dated Thu, 31 Aug 2006, [email protected] writes >Derek, as you have been advised by previous email, 55014-1 and 55014-2 >are the correct standards.
Plus EN 61000-3-2 and EN 61000-3-3. >I would advise one other thing however. Except for toys 55014-1 only >goes to 300 MHz for emissions (disturbance power). There was a hair >dryer case that went to court (Great Britain I believe) in which the >manufacturer lost the case because they did not test to 1000 MHz for >emissions even though 55014 (which they used) did not require them to >do so. I would advise scanning radiated emissions to 1000 MHz as well. I wouldn't put anyone off from doing that, BUT the court case was about safety issues; the EMC case was not brought to court. This is because it implied that the EN was defective, and the British Government would have had to refer that to the Commission under Article 8 of the EMC Directive. Public interest considerations indicated that this should not be pursued. A new edition of EN 55014-1 is due to be published at about the end of this year. But it still doesn't cover emissions up to 1 GHz; that is still being studied. > >One other item, EN 50366 (Household and similar electrical appliances - >Electromagnetic fields) which falls under the Low Voltage Directive now >requires the measurement of human exposure to electromagnetic fields >for household and similar electrical appliances. The frequency band of >interest is from 10 Hz to 400 kHz and the limits are listed in Council >Recommendation 1999/519/EC. Yes, this is a product safety matter, not EMC. -- OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk 2006 is YMMVI- Your mileage may vary immensely. John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please visit http://www.messagelabs.com/email ______________________________________________________________________