Grace For questions 1 & 3, the answers are both basically NO, because in cases like these the FINAL equipment configuration designer / manufacturer is responsible for compliance with all the relevant Directives. He must make the final determination and apply the Marking (and do everything else that that requires). CE + CE = CE does not work because a) The law does not require that components should not be marked anyway (and some Directives actually prohibit the marking on components - though most do'nt) although many manufacturers do this because their customers ask for it. b) Only at the final equipment design stage can you assess compliance to the overall equipment standard. Personally, in most instances ( I nearly used the word "cases"!) I would not recommend a case manufacturer to apply the mark for the sake of his own (or his EU importers') protection. If his/their name is on the unit with the CE Marking and the final manufacturer assembler does not do a proper job, then it is possible that the case manufacturer/importer could be incorrectly indentified as the "guilty party" and legal action be taken against them (erroniously!). Hope someone else can answer Q2. Regards John Allen
From: [email protected] [mailto:[email protected]] On Behalf Of Grace Lin Sent: 19 October 2006 06:29 To: [email protected] Subject: CE Questions Dear Members, Question 1: Does an enclosure need to be CE marked for the EU market? My employer sells enclosures for lighting modules. For enclosure alone (such as the one at <http://www.crestron.com/products/show_ roducts.asp?type=commercial&cat=14&subcat=1072&id=1063> http://www.crestron.com/products/show_p oducts.asp?type=commercial&cat=14&subcat=1072&id=1063), I cannot tell which Directive an enclosure applies to from the list of New Approach directives <http://ec.europa.eu/enterprise/newapp oach/standardization/harmstds/reflist.html> http://ec.europa.eu/enterprise/newappro ch/standardization/harmstds/reflist.html ). Question 2: What is the safety standard applying to a dimmer module like the one at <http://www.crestron.com/products/show_ roducts.asp?type=commercial&cat=14&subcat=1007&id=1077> http://www.crestron.com/products/show_p oducts.asp?type=commercial&cat=14&subcat=1007&id=1077? I assume (please correct me if I am wrong) EN55015 and EN61547 are the EMC test standards. Question 3: IF a CE mark applies to an enclosure from Question 1 and a lighting module is CE marked, can I say the lighting module(s) in an enclosure is CE marked ( i.e., CE+CE=CE?). Question 4: Does everything selling to the Europe needs CE marked? Thank you very much for your time and look forward to your help. Best regards, Grace Lin Sr. Compliance Engineer Crestron Electronics, Inc. 6 Volvo Drive Rockleigh, NJ 07920 <http://www.crestron.com/> www.crestron.com - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc -- No virus found in this incoming message. Checked by AVG Free Edition. Version: 7.1.408 / Virus Database: 268.13.9/490 - Release Date: 20/10/06 ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please visit http://www.messagelabs.com/email ______________________________________________________________________ -- No virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.1.408 / Virus Database: 268.13.9/490 - Release Date: 20/10/06 - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc