I also had similar issues during audits. I was able to argue that it is impossible to have anything that is EXACTLY any dimension. At issue was the height above the ground plane for a 61000-4-6 conducted immunity test. I was able to back it up by finding precedence in the 61000-4-4 EFT standard stating the 10cm height +/- 10%. I'm sure there are some auditors that would not budge, though. I like the quote "EMC testing is like measuring Jello with a micrometer". Bob R.
--- On Wed, 10/12/11, Harry Ward <[email protected]> wrote: From: Harry Ward <[email protected]> Subject: RE: [PSES] Table Size in Emissions test To: [email protected] Date: Wednesday, October 12, 2011, 12:00 PM Interesting thread………. Several years ago I had a similar issue: The table height was measured by (a well-respected) auditor and deemed to be 79.5cm, not 80cm. Several discussions followed regarding the accuracy/traceability of the auditor’s tape measure, validity of the deficiency etc. Initially I rejected the deficiency but after time just added a 0.5cm board to the table. When in business to make money it’s often easier and quicker to fix the perceived problem than to argue against it. Harry - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at http://product-compliance.oc.ieee.org/ Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher <[email protected]> David Heald <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at http://product-compliance.oc.ieee.org/ Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher <[email protected]> David Heald <[email protected]>