Product A contains some fundamental radio parameters that you have mention 
(modulation, demodulation) and probably some others as well such as Frequency 
accuracy/stability. Does it offer any useful functionality without being 
connected to B?

 

== > Yes, even though it’s not possible to verify all radio parameters because 
Item B is missing, it should be possible to check some relevant requirements in 
the ETSI/EN 301 XXX standards on the TX/RX ports of Item A.

== > No, Item A doesn’t have any functionality when Item B is missing.

 

 

 

Regards

Amund

 

Fra: Charlie Blackham [mailto:[email protected]] 
Sendt: 19. mars 2013 20:12
Til: amund; [email protected]
Emne: RE: [PSES] RTTE - Radio product or not

 

Amund

 

I’d look at it the other way around:

 

Product B isn’t a radio without product A attached, therefore product A is part 
of a radio system and the R&TTE Directive applies.

 

Product A contains some fundamental radio parameters that you have mention 
(modulation, demodulation) and probably some others as well such as Frequency 
accuracy/stability. Does it offer any useful functionality without being 
connected to B?

 

(some other regulatory regimes often only require “certification” of the bit 
that actually “transmits”, but the R&TTE directive is a bit different)

 

Regards

Charlie

 

 

From: Amund Westin [mailto:[email protected]] 
Sent: 19 March 2013 10:41
To: [email protected]
Subject: [PSES] RTTE - Radio product or not

 

Item A: Processing unit. Connection to PC and LAN (not directly to telecom 
network). Radio modulator & demodulator. Output radio signal 800MHz / 0dbm on 
cable to Item B.

Item B: Upconverter to 10GHz and High Power Amplifier and antenna

 

Item A and B together is a complete radio system and RTTE apply.

 

Item A stand-alone: I would say that it’s not a radio product since it does not 
transmit / receive to space. The radio signals (TX and RX) in on the cable to 
Item B and could be categorized as a signal line. LAN connection is not 
directly coupled to public telecom network. RTTE will not apply, that’s my 
opinion. The system integrator (Item A + B) will put his system into use and 
should be responsible for fulfilling RTTE.

 

Folks, do you agree?

 

 

Cheers,

Amund  

 

PS: 

>From RTTE guidelines: Telecommunications terminal equipment is defined as a 
>product enabling communication or a relevant component thereof which is 
>intended to be connected directly or indirectly by any means

 

The wording “indirect” makes maybe Item A to a telecom terminal equipment ….

 

-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to