Lighter re-fill fluid (as used in Zippo type cigarette lighters) is a pretty 
good match for the solvent required and comes in handy sized containers from 
many high street locations. 

Nick. 




On 26 Mar 2013, at 18:32, "Gelfand, David" <[email protected]> wrote:

> Is there a product I can buy at the hardware store that is roughly equivalent 
> to the hexane specified in durability test:
> 
> " The petroleum spirit to be used for the test is aliphatic solvent hexane 
> having a maximum aromatics content of 0,1 % by volume, a kauributenol value 
> of 29, an initial boiling point of approximately 65 °C, a dry point of 
> approximately 69 °C and a mass per unit volume of approximately 0,7 kg/l." 
> 
> Thanks in advance.
> 
> David
> Kontron Canada Inc.
> 
> -
> ----------------------------------------------------------------
> This message is from the IEEE Product Safety Engineering Society emc-pstc 
> discussion list. To post a message to the list, send your e-mail to 
> <[email protected]>
> 
> All emc-pstc postings are archived and searchable on the web at:
> http://www.ieee-pses.org/emc-pstc.html
> 
> Attachments are not permitted but the IEEE PSES Online Communities site at 
> http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
> formats), large files, etc.
> 
> Website:  http://www.ieee-pses.org/
> Instructions:  http://listserv.ieee.org/request/user-guide.html
> List rules: http://www.ieee-pses.org/listrules.html
> 
> For help, send mail to the list administrators:
> Scott Douglas <[email protected]>
> Mike Cantwell <[email protected]>
> 
> For policy questions, send mail to:
> Jim Bacher:  <[email protected]>
> David Heald: <[email protected]>

Nick Williams
Director
Direct line: +44 1298 873811
Mobile: +44 7702 995135
email: [email protected]

-----

Conformance Ltd - Product safety, approvals and CE-marking consultants
The Old Methodist Chapel, Great Hucklow, Buxton, SK17 8RG England
Tel. +44 1298 873800, Fax. +44 1298 873801, www.conformance.co.uk
Registered in England, Company No. 3478646


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>