In message <[email protected]>, dated Mon, 9 Sep 2013, Bill Owsley <[email protected]> writes:

Indeed... the protection scheme that passes Safety, causes the system to 'fail safe'  which does not meet the EMC immunity requirements

Plain EMC requirements do not consider fault conditions. Functional EMC requirements do.
--
OOO - Own Opinions Only. With best wishes. See www.jmwa.demon.co.uk
If dictionaries were correct, we would only need one, because they would all
give the same information.
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-
----------------------------------------------------------------