> >           net Xpos-cmd axis.0.motor-pos-cmd => pid.0.command
> >           net Xpos-cmd axis.3.motor-pos-cmd => pid.3.command
> >
> > The program gives an error and is closed.
> 
> It would be a great help if you could tell us what the error was that
> caused it to close.
> 

your signal name is the same for both axis 
change the signal names (eg  X1pos-cmd  and  X2pos-cmd )

Chris M
                                          